- General Information
- Manufacturer
- Server Technology, Inc
- Manufacturer Website Address
- http://www.servertech.com
- Brand Name
- Server Technology
- Product Series
- PRO1
- Product Type
- PDU
The Server Technology® PRO1 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billinggrade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Primary"PDU can be connected to as many as three (with optional module) PRO1 Switched "Link"PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
- Warranty
- Limited Warranty
- 2 Year
- Technical Information
- PDU Type
- Switched
- Phase
- Three Phase
- Plug/Connector Type
- IEC 2P+PE 6Hr 230V/32A
- Receptacle Type
- IEC 60320 C13
- Receptacle Detail
- 8 x IEC 60320 C13
- Protection Type
- Branch Circuit
- Circuit Protection
- Circuit Breaker
- Fuse
- Locking Receptacles
- P-Lock
- Features
- LED Display
- Load Capacity (Watt)
- 7300 W
- Power Description
- Input Voltage
- 230 V AC
- Output Voltage
- 230 V AC
- Power Rating (Watt)
- 7300 W
- Input Current
- 32 A
- Input Frequency
- 60 Hz
- Circuit Breaker
- Yes
- Management
- Management
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- v3 (GET, SET, Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
- Remote Outlet Switching
- Yes
- Interfaces/Ports
- Network (RJ-45)
- Yes
- Physical Characteristics
- Mount Type
- Rack-mountable
- Cabinet-mountable
- Rack Height
- 1U
- Height
- 1.8"
- Width
- 17.2"
- Depth
- 7"
- Environmental Conditions
- Minimum Operating Temperature
- 32°F (0°C)
- Maximum Operating Temperature
- 140°F (60°C)
- Minimum Operating Humidity
- 8%
- Maximum Operating Humidity
- 90%
- Minimum Storage Temperature
- -40°F (-40°C)
- Maximum Storage Temperature
- 185°F (85°C)
- Miscellaneous
- Application/Usage
- Server Rack/Cabinet
- Data Center
- Certifications & Standards
Safety:
- ENIEC 62368-1 (TUVR certified, T-mark)
- IEC 62368-1 incl. regional, national and harmonized differences (IECEE CB scheme) EMC
EMC:
- EN55032 / CISPR 32
- EN55035 / CISPR 35
- EN61000-3-2 / IEC 61000-3-2
- EN61000-3-3 / IEC 61000-3-3
CE Mark:
- 2011/65/EU (RoHS Directive)
- 2014/35/EU (Low Voltage Directive)
- 2014/30/EU (EMC Directive)
UKCA Mark:
- Electrical Equipment (Safety)
- Electromagnetic Compatibility
- Environmental Compliance
- Restriction of Hazardous Substances (RoHS)